Measuring methods, thermal

The measured value pick-ups for the thermal measuring method are electrical resistors and part of a measurement bridge circuit (Figure 2). They may be in the actual flow channel (inline instrument) or wound around the flow channel (bypass instrument).

Simplified electrical diagram of the measurement bridge circuit (resistors placed directly in the flow channel)